To schedule time on DPW Lab resources
To view available time on any instrument, please log in to our viewable calendar
Login: imaging.calendars
Password: MICuser
To schedule time, please contact Julie Prior or Erin Jackson.

 

IVIS 50
Calendar Information:
Special instructions:
  • Available time is limited to staff/instrument availability.
Additional information:
  • Xenogen in vivo Imaging System (IVIS) 50
  • Noninvasive in vivo bioluminescent imaging
  • Camera range: full visible and near IR
  • Filters: <510 nm, >610 nm, >650 nm, 540DF20 nm, 575DF20 nm
  • Automated camera and filter control
  • 1024 x 1024 pixel resolution (13µ/pixel)
  • Maximum number of 2 mice/scan or 1 plate/scan
  • Temperature-controlled heated stages
  • Anesthesia (Isofluorane) setup
  • Western blot analysis
For help with this resource contact: Julie Prior
Erin Jackson
Lynne Collins


IVIS 100
Calendar Information:
Special instructions:
  • Tuesday and Thursday afternoons are reserved for DPW lab use only.
  • Available time is limited to staff/instrument availability.
Additional information:
  • Xenogen in vivo Imaging System (IVIS) 100
  • Noninvasive in vivo bioluminescent imaging
  • Camera range: full visible and near IR
  • Filters: <510 nm, 500-570 nm, >590 nm, 540AF20 nm, 570DF20 nm, 650 nm
  • Automated camera and filter control
  • 2048 x 2048 pixel resolution (13.5µ/pixel)
  • Maximum number of 5 mice/scan (2 typical) or 3 plates/scan (1 typical)
  • Anesthesia (Isofluorane) setup
  • Temperature-controlled heated stages
  • 5% CO2 atmosphere
  • Western blot analysis
For help with this resource contact: Julie Prior
Erin Jackson
Lynne Collins


Kodak
Calendar Information:
Special instructions:
  • Available time is limited to staff/instrument availability.
Additional information:
  • Kodak In-Vivo IS4000MM Imaging System
  • Noninvasive in vivo fluorescence, radioisotopic, and X-Ray imaging
  • Anesthesia (Isofluorane) setup
  • 4,000,000 pixel resolution (10µ/pixel)
  • Manual zoom from 140x140 mm into 20x20 mm
  • 1 mouse/scan or 1 plate/scan
  • Fluorescent Excitation Filters: 465 nm, 535 nm
  • Fluorescent Emission Filters: 535 nm, 830 nm, 670 nm, 790 nm, 690 nm
  • Western blot analysis
For help with this resource contact: Dustin Maxwell
Julie Prior
Erin Jackson


NanoSPECT/CT
Calendar Information:
Special instructions:
  • Initial request for use needs to be made one week prior to planned experiment date to allow for instrument and billing setup.
  • Training available upon request and required for independent studies.
Additional information:
  • Bioscan NanoSPECT/CT
  • Noninvasive in vivo SPECT imaging with co-registration to CT
  • Mouse and Rat imaging
  • SPECT or planar scintigraphy and CT imaging capabilities
For help with this resource contact: Erin Jackson
 