IVIS 100 IVIS 50 MS FX Onyx NanoSPECT/CT LC/MS
Back to Research
Back to Scheduling
| Caliper Life Sciences |
- Noninvasive in vivo bioluminescent imaging
- Automated camera and filter control
- Camera range: full visible and near IR
- Filters: <510 nm, 500-570 nm, >590 nm, 540AF20 nm, 570DF20 nm, 650 nm
- 2048 x 2048 pixel resolution (13.5µ/pixel)
- Western blot analysis
- Maximum number of 5 mice at a time (2 typical)
- Anesthesia (Isofluorane) setup
- Maximum number of 3 plates at a time (1 typical)
- Temperature-controlled heated stages
- 5% CO2 atmosphere
|
| For help with this resource contact: |
Julie Prior
Erin (Jackson) Smith
Lynne Collins |
| Caliper Life Sciences |
- Noninvasive in vivo bioluminescent imaging
- Automated camera and filter control
- Camera range: full visible and near IR
- Filters: <510 nm, >610 nm, >650 nm, 540DF20 nm, 575DF20 nm
- 1024 x 1024 pixel resolution (13µ/pixel)
- Western blot analysis
- Maximum number of 2 mice at a time
- Anesthesia (Isofluorane) setup
- Maximum number of 1 plate at a time
- Temperature-controlled heated stages
- 5% CO2 atmosphere
|
| For help with this resource contact: |
Julie Prior
Erin (Jackson) Smith
Lynne Collins |
| Carestream Health |
- Noninvasive in vivo fluorescence, radioisotopic, and X-Ray imaging
- 4,000,000 pixel resolution (10µ/pixel)
- Continuous zoom from 200x200 mm into 20x20 mm
- Fluorescent Excitation Filters: 410 nm - 760 nm
- Fluorescent Emission Filters: 535 nm - 850 nm
- Western blot analysis
- Anesthesia (Isofluorane) setup
- 1 mouse at a time
|
| For help with this resource contact: |
Julie Prior |
| Stanford Photonics |
- Non-invasive in vivo and in cellulo bioluminescence imaging, Cherenkov radiation imaging
- Stanford Photonics XR/MEGA-10Z ICCD camera
- Visible and near IR spectral range
- Near-zero background noise (no background subtraction needed)
- ~1.4 megapixel resolution
- Swappable custom filters
- Up to 55 acquisitions per second
- Customizable optics
- Maximum number of 2 mice at a time
- Anesthesia (Isofluorane) setup
- 1 plate at a time
- 5% CO2 atmosphere
- Temperature controlled heated stage platform
- Umlimited imaging sequence/integration time
- Single cell resolution and sensistivity
|
| For help with this resource contact: |
Julie Prior
Reece Goiffon |
| Bioscan |
- Noninvasive in vivo SPECT imaging with co-registration to CT
- SPECT or planar scintigraphy with CT imaging capabilities
- Energy range: 25-250 keV
- Multi-isotope imaging capable
- Absolute quantification when study is performed with a phantom calibration
- Mouse and Rat imaging
- Anesthesia (Isofluorane) setup
- Maximum number of 3 mice at a time (1 typical) or 1 rat at a time
|
| For help with this resource contact: |
Scott Harpstrite |
| Agilent |
- 500 Ion Trap LC/MS MS/MS System
- 500 Ion Trap ESI / APCI Option with turbo molecular vacuum pumps
- Turbo DDS for extended mass range up to 3000 m/z
- LCMS LC, 260 L TI DYN. MIXPEEK PLUM
- 460-LC Auto sampler, 95-240V
- 325 UV/VIS Dual Wavelength Detector
|
| For help with this resource contact: |
Scott Harpstrite
GSM Sundaram |
Back to Research